ESD241-B1-W0201 E6327 数据手册
ESD241-B1-W0201
Protection Devices
TVS (Transient Voltage Suppressor)
Bi-directional, 3.3 V, 6.5 pF, 0201, RoHS and Halogen Free compliant
Feature list
•
•
•
•
•
•
•
ESD/transient protection according to:
- IEC61000-4-2 (ESD): ±18 kV (air/contact discharge)
- IEC61000-4-4 (EFT): ±2 kV/±40 A (5/50 ns)
- IEC61000-4-5 (Surge): ±4.5 A (8/20 μs)
Bi-directional working voltage up to: VRWM = ±3.3 V
Line capacitance: CL = 6.5 pF (typical) at f = 1 MHz
Clamping voltage: VCL = 6 V (typical) at ITLP = 16 A with RDYN = 0.09 Ω (typical)
Very low reverse current: IR < 1 nA (typical)
Small form factor SMD size 0201, low profile (0.58 mm x 0.28 mm x 0.15 mm) [3]
Bi-directional, symmetric I/V characteristic for optimized design and assembly,
recommendations for PCB assembly see [2]
Potential applications
•
•
IC/ASICs in audio, headset
Human digital interfaces, buttons, GPIO
Product validation
Qualified for industrial applications according to the relevant tests of JEDEC47/20/22
Device information
a ) Pin configuration
Figure 1
Pin configuration and schematic diagram
Table 1
Part information
b ) Schematic diagram
Type
Package
Configuration
Marking code
ESD241-B1-W0201
WLL-2-3
1 line, bi-directional
AC 1)
1
The device has no marking on the device top. The marking code is on the pad side.
Datasheet
www.infineon.com
Please read the Important Notice and Warnings at the end of this document
Revision 1.2
2018-03-19
ESD241-B1-W0201
Protection Devices
Table of contents
Table of contents
Feature list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Potential applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Product validation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Device information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Table of contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1
Maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2
Electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3
Typical characteristic diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4
4.1
Package information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
WLL-2-3 package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5
References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Datasheet
2
Revision 1.2
2018-03-19
ESD241-B1-W0201
Protection Devices
Maximum ratings
1
Maximum ratings
Note:
TA = 25 °C, unless otherwise specified
Table 2
Maximum ratings
Parameter
Symbol
Values
Unit
Reverse working voltage
VRWM
±3.3
V
ESD discharge 1)
VESD (contact)
±18
kV
VESD (air)
±18
Peak pulse power 2)
PPK
25
W
Peak pulse current 2)
IPP
±4.5
A
Operating temperature range
TOP
-55 to 125
°C
Storage temperature
Tstg
-65 to 150
°C
Attention: Stresses above the maximum values listed here may cause permanent damage to the device.
Exposure to absolute maximum rating conditions for extended periods may affect device
reliability. Maximum ratings are absolute ratings. Exceeding only one of these values may cause
irreversible damage to the component.
1
2
VESD according to IEC61000-4-2 (R = 330 Ω, C = 150 pF discharge network)
Stress pulse: 8/20μs current waveform according to IEC61000-4-5
Datasheet
3
Revision 1.2
2018-03-19
ESD241-B1-W0201
Protection Devices
Electrical characteristics
2
Electrical characteristics
Note:
TA = 25°C, unless otherwise specified. Device is electrically symmetrical.
IF
I PP
I TLP
VR
VF
IF
... Forward voltage
VR
IR
... Reverse voltage
RDYN
... Forward current
ΔV
ΔI
ΔI
... Reverse current
VCL
VTLP Vt1 Vh VRWM
IR
IT
IR
VRWM Vh
IT
ΔI
ΔV
RDYN
ΔV
ΔI
I PP
I TLP
IR
Figure 2
Datasheet
ΔV
RDYN
VRWM
Vt1
Vh
VCL
VTLP
IR
Ipp
ITLP
IT
Vt1 VCL
VTLP
VF
... Dynamic resistance
... Reverse working voltage max.
... Trigger voltage
... Holding voltage
... Clamping voltage
... TLP voltage
... Reverse leakage current
... Peak pulse current
... TLP current
... Test current
Diode_Characteristic_Curve_with_snapback_Bi-directional.svg
Definitions of electrical characteristics
4
Revision 1.2
2018-03-19
ESD241-B1-W0201
Protection Devices
Electrical characteristics
Table 3
DC characteristics
Parameter
Symbol
Values
Min.
Typ.
Unit
Note or test condition
Max.
Trigger Voltage1)2)
Vt1
5
6
7.5
V
–
Holding voltage3)
Vh
4
5.7
7.2
V
IT = 1 mA
Reverse current
IR
–
1
30
nA
VR = 3.3 V
Unit
Note or test condition
pF
VR = 0 V, f = 1 MHz
Table 4
AC characteristics
Parameter
Symbol
Values
Min.
Line capacitance
Table 5
CL
Typ.
–
6.5
–
–
6.5
–
Symbol
Values
Min.
Clamping voltage 4)
VCL
Clamping voltage 5)
Dynamic resistance 4)
2
3
4
5
VR = 0 V, f = 1 GHz
ESD and Surge characteristics
Parameter
1
Max.
RDYN
Typ.
Unit
Note or test condition
V
ITLP = 16 A, tp = 100 ns
Max.
–
6
–
–
7
–
ITLP = 30 A, tp = 100 ns
–
5
–
IPP = 1 A, tp = 8/20 µs
–
6
–
IPP = 4 A, tp = 8/20 µs
–
0.09
–
Ω
tp = 100 ns
Verified by design
Voltage forced
Current forced
Please refer to Application Note AN210 [1]. TLP parameters: Z0 = 50 Ω , tp = 100ns, tr = 0.6 ns.
Stress pulse: 8/20μs current waveform according to IEC61000-4-5
Datasheet
5
Revision 1.2
2018-03-19
ESD241-B1-W0201
Protection Devices
Typical characteristic diagrams
3
Typical characteristic diagrams
Note:
TA = 25 °C, unless otherwise specified
10-6
10-7
10-8
IR [A]
10-9
-10
10
10-11
-12
10
-13
10
Figure 3
-3.5 -3 -2.5 -2 -1.5 -1 -0.5 0 0.5
VR [V]
1
1.5
2
2.5
3
3.5
3
3.5
Reverse leakage current: IR = f(VR)
8
7
6
CL [pF]
5
4
3
2
1
0
-3.5
Figure 4
Datasheet
-3
-2.5
-2
-1.5
-1
-0.5
0 0.5
VR [V]
1
1.5
2
2.5
Line capacitance: CL = f(VR), f = 1 MHz
6
Revision 1.2
2018-03-19
ESD241-B1-W0201
Protection Devices
Typical characteristic diagrams
25
Scope: 6 GHz, 20 GS/s
20
VCL [V]
15
VCL-max-peak = 20 V
10
VCL-30ns-peak = 6 V
5
0
-5
-50
Figure 5
0
50
100
150
200
tp [ns]
250
300
350
400
450
Clamping voltage (ESD): VCL = f(Vt), 8 kV positive pulse (according to IEC61000-4-2)
5
Scope: 6 GHz, 20 GS/s
0
VCL [V]
-5
-10
-15
VCL-max-peak = -21 V
-20
VCL-30ns-peak = -6 V
-25
-50
0
50
100
150
200
tp [ns]
250
300
350
400
450
Figure 6
Clamping voltage (ESD): VCL = f(Vt), 8 kV negative pulse (according to IEC 61000-4-2)
Datasheet
7
Revision 1.2
2018-03-19
ESD241-B1-W0201
Protection Devices
Typical characteristic diagrams
35
Scope: 6 GHz, 20 GS/s
30
25
VCL [V]
20
VCL-max-peak = 32 V
15
VCL-30ns-peak = 7 V
10
5
0
-5
-50
Figure 7
0
50
100
150
200
tp [ns]
250
300
350
400
450
Clamping voltage (ESD): f(VCL) = f(Vt), 15 kV positive pulse (according to IEC61000-4-2)
5
Scope: 6 GHz, 20 GS/s
0
-5
VCL [V]
-10
-15
-20
VCL-max-peak = -31 V
-25
VCL-30ns-peak = -7 V
-30
-35
-50
Figure 8
Datasheet
0
50
100
150
200
tp [ns]
250
300
350
400
450
Clamping voltage (ESD): VCL = f(Vt), 15 kV negative pulse (according to IEC61000-4-2)
8
Revision 1.2
2018-03-19
ESD241-B1-W0201
Protection Devices
Typical characteristic diagrams
17.5
ESD241-B1-W0201
RDYN
30
15
RDYN = 0.09 Ω
ITLP [A]
25
12.5
20
10
15
7.5
10
5
5
2.5
0
0
-5
-2.5
-10
-5
-15
-7.5
-20
-10
RDYN = 0.09 Ω
-25
-12.5
-30
-35
-10
Equivalent VIEC [kV]
35
-15
-8
-6
-4
-2
0
2
4
6
8
-17.5
10
VTLP [V]
Figure 9
Datasheet
Clamping voltage (TLP):ITLP = f(VTLP) [1]
9
Revision 1.2
2018-03-19
ESD241-B1-W0201
Protection Devices
Typical characteristic diagrams
5
4
3
2
IPP [A]
1
0
-1
-2
-3
-4
-5
-10
Figure 10
Datasheet
-5
0
VCL [V]
5
10
Clamping voltage (Surge): IPP = f(VCL) (according to IEC61000-4-5) [1]
10
Revision 1.2
2018-03-19
ESD241-B1-W0201
Protection Devices
Package information
4
Package information
4.1
WLL-2-3 package
Note:
Dimensions in mm
BOTTOM VIEW
0.28±0.03
0.15±0.01
0.24±0.02
0.17±0.02
0.36
(0.19)
0.58±0.03
1
2
ALL DIMENSIONS ARE IN UNITS MM
THE DRAWING IS IN COMPLIANCE WITH ISO 128 & PROJECTION METHOD 1 [
Figure 11
]
WLL-2-3 package outline
0.37
0.18
0.25
0.37
0.3
STENCIL THICKNESS
ESD241-B1-W0201 E6327 价格&库存
很抱歉,暂时无法提供与“ESD241-B1-W0201 E6327”相匹配的价格&库存,您可以联系我们找货
免费人工找货