ESD241-B1-W0201 E6327

ESD241-B1-W0201 E6327

  • 厂商:

    EUPEC(英飞凌)

  • 封装:

    WLL2-3

  • 描述:

    ESD241-B1-W0201 E6327

  • 数据手册
  • 价格&库存
ESD241-B1-W0201 E6327 数据手册
ESD241-B1-W0201 Protection Devices TVS (Transient Voltage Suppressor) Bi-directional, 3.3 V, 6.5 pF, 0201, RoHS and Halogen Free compliant Feature list • • • • • • • ESD/transient protection according to: - IEC61000-4-2 (ESD): ±18 kV (air/contact discharge) - IEC61000-4-4 (EFT): ±2 kV/±40 A (5/50 ns) - IEC61000-4-5 (Surge): ±4.5 A (8/20 μs) Bi-directional working voltage up to: VRWM = ±3.3 V Line capacitance: CL = 6.5 pF (typical) at f = 1 MHz Clamping voltage: VCL = 6 V (typical) at ITLP = 16 A with RDYN = 0.09 Ω (typical) Very low reverse current: IR < 1 nA (typical) Small form factor SMD size 0201, low profile (0.58 mm x 0.28 mm x 0.15 mm) [3] Bi-directional, symmetric I/V characteristic for optimized design and assembly, recommendations for PCB assembly see [2] Potential applications • • IC/ASICs in audio, headset Human digital interfaces, buttons, GPIO Product validation Qualified for industrial applications according to the relevant tests of JEDEC47/20/22 Device information a ) Pin configuration Figure 1 Pin configuration and schematic diagram Table 1 Part information b ) Schematic diagram Type Package Configuration Marking code ESD241-B1-W0201 WLL-2-3 1 line, bi-directional AC 1) 1 The device has no marking on the device top. The marking code is on the pad side. Datasheet www.infineon.com Please read the Important Notice and Warnings at the end of this document Revision 1.2 2018-03-19 ESD241-B1-W0201 Protection Devices Table of contents Table of contents Feature list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Potential applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Product validation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Device information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Table of contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1 Maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2 Electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3 Typical characteristic diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 4 4.1 Package information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 WLL-2-3 package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 5 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Datasheet 2 Revision 1.2 2018-03-19 ESD241-B1-W0201 Protection Devices Maximum ratings 1 Maximum ratings Note: TA = 25 °C, unless otherwise specified Table 2 Maximum ratings Parameter Symbol Values Unit Reverse working voltage VRWM ±3.3 V ESD discharge 1) VESD (contact) ±18 kV VESD (air) ±18 Peak pulse power 2) PPK 25 W Peak pulse current 2) IPP ±4.5 A Operating temperature range TOP -55 to 125 °C Storage temperature Tstg -65 to 150 °C Attention: Stresses above the maximum values listed here may cause permanent damage to the device. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Maximum ratings are absolute ratings. Exceeding only one of these values may cause irreversible damage to the component. 1 2 VESD according to IEC61000-4-2 (R = 330 Ω, C = 150 pF discharge network) Stress pulse: 8/20μs current waveform according to IEC61000-4-5 Datasheet 3 Revision 1.2 2018-03-19 ESD241-B1-W0201 Protection Devices Electrical characteristics 2 Electrical characteristics Note: TA = 25°C, unless otherwise specified. Device is electrically symmetrical. IF I PP I TLP VR VF IF ... Forward voltage VR IR ... Reverse voltage RDYN ... Forward current ΔV ΔI ΔI ... Reverse current VCL VTLP Vt1 Vh VRWM IR IT IR VRWM Vh IT ΔI ΔV RDYN ΔV ΔI I PP I TLP IR Figure 2 Datasheet ΔV RDYN VRWM Vt1 Vh VCL VTLP IR Ipp ITLP IT Vt1 VCL VTLP VF ... Dynamic resistance ... Reverse working voltage max. ... Trigger voltage ... Holding voltage ... Clamping voltage ... TLP voltage ... Reverse leakage current ... Peak pulse current ... TLP current ... Test current Diode_Characteristic_Curve_with_snapback_Bi-directional.svg Definitions of electrical characteristics 4 Revision 1.2 2018-03-19 ESD241-B1-W0201 Protection Devices Electrical characteristics Table 3 DC characteristics Parameter Symbol Values Min. Typ. Unit Note or test condition Max. Trigger Voltage1)2) Vt1 5 6 7.5 V – Holding voltage3) Vh 4 5.7 7.2 V IT = 1 mA Reverse current IR – 1 30 nA VR = 3.3 V Unit Note or test condition pF VR = 0 V, f = 1 MHz Table 4 AC characteristics Parameter Symbol Values Min. Line capacitance Table 5 CL Typ. – 6.5 – – 6.5 – Symbol Values Min. Clamping voltage 4) VCL Clamping voltage 5) Dynamic resistance 4) 2 3 4 5 VR = 0 V, f = 1 GHz ESD and Surge characteristics Parameter 1 Max. RDYN Typ. Unit Note or test condition V ITLP = 16 A, tp = 100 ns Max. – 6 – – 7 – ITLP = 30 A, tp = 100 ns – 5 – IPP = 1 A, tp = 8/20 µs – 6 – IPP = 4 A, tp = 8/20 µs – 0.09 – Ω tp = 100 ns Verified by design Voltage forced Current forced Please refer to Application Note AN210 [1]. TLP parameters: Z0 = 50 Ω , tp = 100ns, tr = 0.6 ns. Stress pulse: 8/20μs current waveform according to IEC61000-4-5 Datasheet 5 Revision 1.2 2018-03-19 ESD241-B1-W0201 Protection Devices Typical characteristic diagrams 3 Typical characteristic diagrams Note: TA = 25 °C, unless otherwise specified 10-6 10-7 10-8 IR [A] 10-9 -10 10 10-11 -12 10 -13 10 Figure 3 -3.5 -3 -2.5 -2 -1.5 -1 -0.5 0 0.5 VR [V] 1 1.5 2 2.5 3 3.5 3 3.5 Reverse leakage current: IR = f(VR) 8 7 6 CL [pF] 5 4 3 2 1 0 -3.5 Figure 4 Datasheet -3 -2.5 -2 -1.5 -1 -0.5 0 0.5 VR [V] 1 1.5 2 2.5 Line capacitance: CL = f(VR), f = 1 MHz 6 Revision 1.2 2018-03-19 ESD241-B1-W0201 Protection Devices Typical characteristic diagrams 25 Scope: 6 GHz, 20 GS/s 20 VCL [V] 15 VCL-max-peak = 20 V 10 VCL-30ns-peak = 6 V 5 0 -5 -50 Figure 5 0 50 100 150 200 tp [ns] 250 300 350 400 450 Clamping voltage (ESD): VCL = f(Vt), 8 kV positive pulse (according to IEC61000-4-2) 5 Scope: 6 GHz, 20 GS/s 0 VCL [V] -5 -10 -15 VCL-max-peak = -21 V -20 VCL-30ns-peak = -6 V -25 -50 0 50 100 150 200 tp [ns] 250 300 350 400 450 Figure 6 Clamping voltage (ESD): VCL = f(Vt), 8 kV negative pulse (according to IEC 61000-4-2) Datasheet 7 Revision 1.2 2018-03-19 ESD241-B1-W0201 Protection Devices Typical characteristic diagrams 35 Scope: 6 GHz, 20 GS/s 30 25 VCL [V] 20 VCL-max-peak = 32 V 15 VCL-30ns-peak = 7 V 10 5 0 -5 -50 Figure 7 0 50 100 150 200 tp [ns] 250 300 350 400 450 Clamping voltage (ESD): f(VCL) = f(Vt), 15 kV positive pulse (according to IEC61000-4-2) 5 Scope: 6 GHz, 20 GS/s 0 -5 VCL [V] -10 -15 -20 VCL-max-peak = -31 V -25 VCL-30ns-peak = -7 V -30 -35 -50 Figure 8 Datasheet 0 50 100 150 200 tp [ns] 250 300 350 400 450 Clamping voltage (ESD): VCL = f(Vt), 15 kV negative pulse (according to IEC61000-4-2) 8 Revision 1.2 2018-03-19 ESD241-B1-W0201 Protection Devices Typical characteristic diagrams 17.5 ESD241-B1-W0201 RDYN 30 15 RDYN = 0.09 Ω ITLP [A] 25 12.5 20 10 15 7.5 10 5 5 2.5 0 0 -5 -2.5 -10 -5 -15 -7.5 -20 -10 RDYN = 0.09 Ω -25 -12.5 -30 -35 -10 Equivalent VIEC [kV] 35 -15 -8 -6 -4 -2 0 2 4 6 8 -17.5 10 VTLP [V] Figure 9 Datasheet Clamping voltage (TLP):ITLP = f(VTLP) [1] 9 Revision 1.2 2018-03-19 ESD241-B1-W0201 Protection Devices Typical characteristic diagrams 5 4 3 2 IPP [A] 1 0 -1 -2 -3 -4 -5 -10 Figure 10 Datasheet -5 0 VCL [V] 5 10 Clamping voltage (Surge): IPP = f(VCL) (according to IEC61000-4-5) [1] 10 Revision 1.2 2018-03-19 ESD241-B1-W0201 Protection Devices Package information 4 Package information 4.1 WLL-2-3 package Note: Dimensions in mm BOTTOM VIEW 0.28±0.03 0.15±0.01 0.24±0.02 0.17±0.02 0.36 (0.19) 0.58±0.03 1 2 ALL DIMENSIONS ARE IN UNITS MM THE DRAWING IS IN COMPLIANCE WITH ISO 128 & PROJECTION METHOD 1 [ Figure 11 ] WLL-2-3 package outline 0.37 0.18 0.25 0.37 0.3 STENCIL THICKNESS
ESD241-B1-W0201 E6327 价格&库存

很抱歉,暂时无法提供与“ESD241-B1-W0201 E6327”相匹配的价格&库存,您可以联系我们找货

免费人工找货